Medical Device PCB Assembly in China for a First Order of 100 Boards

Buyer Guide

Medical Device PCB Assembly in China for a First Order of 100 Boards

Updated November 25, 2026

Yes. BELI Technologies, a PCB assembly supplier in Shenzhen, takes a first medical-device order of about 100 boards as a small batch, with a sample batch before it if you want one: there is no minimum order quantity for prototypes. BELI’s manufacturing facilities are certified to ISO 9001:2015, ISO 14001 and ISO 13485:2016. BELI signs an NDA before you share Gerbers, BOMs or schematics, and your own NDA template is accepted. Every order gets AOI, X-ray and an electrical test, and ships with a certificate of conformance, a first article inspection report, the functional test report and a component lot and date-code list. Each board batch can be traced to the component lots and date codes used to build it.

Key facts
Quality systemBELI’s manufacturing facilities are certified to ISO 9001:2015, ISO 14001 and ISO 13485:2016
First orderA sample batch first, then about 100 boards; no MOQ for prototypes
NDASigned before you share files; your own NDA template is accepted
TraceabilityEach board batch traced to component lots and date codes
Inspection and testAOI and X-ray on every order; electrical test on every order
Documents with every orderCoC, FAI report, functional test report, lot and date-code list, ISO certificate copies

Can I place a first medical order of about 100 boards?

Yes. BELI builds assembled boards from the customer’s own Gerber files and BOM for medical-device companies, from prototype and pilot run through to volume production, and there is no minimum order quantity for prototypes — a single board is a valid order. A first order of about 100 boards runs as a small batch on the same SMT lines as volume production, so the evidence gathered on the first order stays relevant when the quantity grows. AOI and X-ray inspection run on every order. Capability and scope are on the medical device PCB assembly page.

How does sample evaluation work before the 100-board order?

Order a sample batch first and evaluate it against your drawing and test specification. Samples are built from the same Gerber files and BOM as the later order, on the same SMT lines, and ship with the same records: the first article inspection (FAI) report, AOI and X-ray inspection records or images, the functional test report and BELI’s certificate of conformance. Quick-turn prototype assembly takes 48 hours once boards and components are in hand; turnkey orders that include component sourcing typically take 2–3 weeks. Stencils and test fixtures are kept for repeat orders.

Will you sign an NDA before we send the design files?

Yes. BELI signs an NDA before you share Gerbers, BOMs or schematics, and your own NDA template is accepted; BELI’s template is available if you prefer it. Attach your NDA to the first email or to the contact form, and send the design files once it is signed. Every client is assigned a dedicated English-speaking project engineer.

Is a first medical order built in ISO 13485:2016-certified manufacturing facilities?

Yes. BELI’s manufacturing facilities are certified to ISO 9001:2015, ISO 14001 and ISO 13485:2016. ISO 13485:2016 is the quality management standard for the medical-device supply chain, and it certifies how the boards are built: the quality system, process and change control, and traceability. Copies of the ISO certificates of BELI’s manufacturing facilities ship with every order and are provided on request with any RFQ. Each copy shows the registrar, the certified site and the validity dates, so you can confirm the certificate with the issuing registrar for your supplier-qualification file. Assembled boards are inspected to IPC-A-610J.

How is each board batch traced back to its components?

Each board batch can be traced to the component lots and date codes used to build it, and a component lot and date-code list ships with every order. Components are bought from authorized distributors and original manufacturers, and the original manufacturer’s or distributor’s certificate of conformance ships with the order. When an authorized channel has no stock, independent-distributor stock is used only with your written approval. Incoming-inspection records are kept in writing and are available on request. Serial numbers are written to assembled boards to your numbering rules; if your quality file needs traceability to the individual serialised unit, state the marking and record requirement in your build documentation and it is confirmed at quotation.

Which inspections and tests does the first 100-board batch get?

AOI and X-ray inspection run on every order, and every order gets an electrical test: ICT on production runs, at ≥95% node coverage, and flying-probe test on prototypes and small batches. When your specification calls for IPC-A-610 Class 3, assemblies are inspected and accepted to Class 3. Functional test runs to your test plan, on custom fixtures that are built for your product and remain your property. Burn-in up to 72 hours and temperature and humidity screening from −40 to +125 °C at 20–98% RH are available; name the duration and profile in your RFQ. First-pass yield is ≥99.5%.

Who completes FDA or EU MDR registration, and what does BELI supply?

You do, as the legal manufacturer of the device, working with your regulatory consultant, notified body or regulator; product-level testing such as the IEC 60601 series is carried out on the finished device by an accredited laboratory. BELI supplies the manufacturing side of that file: boards built to your released specification, manufacturing records, component traceability and test reports, in the form your file needs. In the RFQ, state the documentation set you need with each shipment, any approved-vendor restrictions and whether changes need your written approval, so they are written into the quotation.

A first medical order of 100 boards, step by step

A first medical order of 100 boards, step by step
StepWhat you provideWhat BELI does
1. NDAYour NDA template, or a request for BELI’sSigns the NDA before you share Gerbers, BOMs or schematics
2. RFQGerber or ODB++ files, BOM with manufacturer part numbers, pick-and-place file, sample and first-order quantities, test specification, IPC-A-610 acceptance classRuns the DFM review; the quotation lists the distributor for each BOM line
3. Sample batchThe sample quantity — a single board is a valid orderBuilds the samples on the same SMT lines as volume production, with AOI, X-ray and flying-probe test
4. Sample evaluationYour evaluation against the drawing and test specification, and any design revisionSupplies the FAI report, inspection records and functional test report with the samples; keeps stencils and test fixtures for repeat orders
5. First order of 100 boardsThe purchase order stating the revision, the acceptance class and the documentation setBuilds, inspects and tests the batch; accepts to IPC-A-610 Class 3 when your specification calls for it. Sample and small-value orders are prepaid in full; every quotation states its payment terms.
6. ShipmentDestination and Incoterm: EXW, FOB Shenzhen, DAP or DDPShips with the quality-document pack; express delivery to North America, Europe and Israel typically takes 3–7 days
7. After deliveryYour incoming inspection and quality-file recordsCarries a minimum 12-month workmanship warranty on assembled boards; each board batch can be traced to its component lots and date codes

Request a quotation

To quote a first medical order, send your Gerber or ODB++ files, the BOM with manufacturer part numbers and any approved-vendor-only or no-substitution lines, the pick-and-place (centroid) file, and the quantities: the sample quantity and the first-order quantity. Add the test specification with pass/fail limits, the IPC-A-610 acceptance class your file requires and the documentation set you need with each shipment. Quotes and inquiry emails are answered within 24 hours, 7 days a week. BELI signs an NDA before you share Gerbers, BOMs or schematics; your own NDA template is accepted.

Send the files to beli@belitechnologies.com or use the contact form. The documents that ship with every order are listed on the quality documents page.

Related pages

Frequently Asked Questions

Are medical boards built in ISO 13485:2016-certified facilities?
Yes. BELI’s manufacturing facilities are certified to ISO 9001:2015, ISO 14001 and ISO 13485:2016. ISO 13485:2016 is the medical-device quality management standard, and copies of the certificates ship with every order, the first one included.
Can I evaluate samples before ordering 100 boards?
Yes. There is no minimum order quantity for prototypes — a single board is a valid order — and samples are built on the same SMT lines as volume production. They ship with the first article inspection report, AOI and X-ray inspection records and the functional test report.
Will BELI sign our own NDA template?
Yes. BELI signs an NDA before you share Gerbers, BOMs or schematics, and your own NDA template is accepted.
What traceability records come with a medical order?
A component lot and date-code list ships with every order, and each board batch can be traced to the component lots and date codes used to build it. The original manufacturer’s or distributor’s certificate of conformance for the components ships with the order too, and incoming-inspection records are available on request.